11. Upgrading the DRM firmware
Note: Follow these directions carefully (contact MGPI for assistance)
1. Install the DRM Firmware Updater software by unzipping the files to a known directory and clicking on the
‘Setup’ in the ‘Installer’ directory.
2. Disconnect the meter from the power supply and ensure that the battery back-up is also turned OFF
; dip
switches 1 and 2 in the OFF position, see figure 2 or 3
3. Set dipswitch 1& 2 to on position
4. Set dipswitch 3 to 8 to off position
5. Open the back meter panel, see figure 2 or 3
6. Switch E1 located at mother board card to update position (upward). See Figure2 for the DRM-1 or Figure
3 DRM-1D
7. Connect the meter to the PC via the RS-232 cable and NULL modem adapter.
8. To start the Firmware Updater software double clicking the ‘Application.exe’ icon in the
known directory.(see next page for screen view)
9. Set the PC Communications Port and load the supplied *.hex file,, i.e. “drm1-4769.hex” located in the
known created directory for the software.
10. Select "send an answer " function 1 (Check)
11. Click on the Start (white arrow) to initialize the program.
12. Connect the meter to the power supply information should appear in the File Read screen.
13. If the menu does not appear, turn (disconnect) the power supply off, click on the stop (red point) icon and
go back to item 10
14. Click on the "send 1" button
15. Check that the right hand window displays “Enter to command > 1 **** Ready to receive
16. Click on "send 2"
17. Check that the right hand window displays “The file was verified and is good for update” Enter
command
18. Select "send an answer " function 2 (Update)
19. Click on "send 1"
20. Check that the right hand window displays “Enter to command > 2 **** Ready to Receive
21. Click on "send 2" wait…
22. Check that the right hand window displays “Firmware update complete” and verify that the information
in the window is exactly like figure 1 before removing the AC power
23. Disconnect the power supply and remove the serial/null cable.
24. Switch E1 located on the motherboard card 2143 to inverse "update" position (downward).
25. Connect the power supply and verify that the meter operates.
26. Ensure Dip Switches 1, 2, and 3 are in the ON position.