3.7. Battery Replacement
Note: The battery compartment is located on the lower right side of the TelePole’s meter.
3.7.1. Slide out the battery compartment cover in the direction of the arrow (open). See Fig. 3-
1.
3.7.2. Insert two C-type alkaline batteries with the correct polarity.
3.7.3. To close of the battery compartment, press the batteries down, place the compartment
cover on the battery edge, press the batteries down with the compartment cover and slide
the cover into place along the side slots.
Using an External Power Supply
Power can be supplied to the meter in one of two ways:
1. Ordinary batteries - default use. When an external 3V DC power supplies is connected, the
internal batteries will be disconnected.
2. Rechargeable batteries - on request. A 2.9V to 3.2V external power supply charges the
batteries. A jumper on the printed circuit performs the interchange.
Warning: Ensure to connect the external power supply with the correct polarity, as indicated
on the instrument battery compartment.
Figure 3-1. TelePole Battery Compartment
4. Communication
4.1. Survey Mapping Communication
The TelePole is compatible with the survey mapping software. An External Laser Scanner or
a Smart Wand (laser pen) may perform the scanning of the bar code. The bar-code reader is
connected to serial port COM-1 located on the instrument rear panel.