TelePole WR/ Operating & Maintenance Manual Page 27
7.1.2. Power Supply
DRW #12850-42-00.
H.V. Board Block Diagram
High Voltage Converter & Internal Geiger (optional)
The high voltage converter and internal geiger components are installed on the board
only when the internal geiger is used. As well, a short is performed on jumper E3. When
the microcontroller identifies the short on E3 via J5/5, the internal geiger is activated.
High Voltage Circuit for the Internal Geiger
The H.V. circuit includes an ORAM 5525 transformer, a voltage multiplier (D4, D5, D6,
C7, C3), and an RV4192 switching regulator.
R10 and R9 are voltage feedback for the switching regulator.
The high voltage, 500V ±5% generated in the H.V. circuit is transmitted to the geiger.
When the Geiger is positioned in a radiation field, positive pulses are obtained on
pin K1 of the Geiger. These pulses are shaped and amplified by Q1, Q4 and RC
components.
Converter
Option
Internal Geiger
3V to 5V
Converter &
Low Battery
Identification
3V to 12V
Converter
WRM
J6
J2
J1
Calibration
Switch
J5
J8
J3